Power Flow Card Plus Fix - Energy Flow Display Correction ✓ SOLVED
Problem Summary
The Power Flow Card Plus was incorrectly showing that all solar production was consumed by home, with no grid feed-in displayed. In reality, the system was feeding excess solar back to the grid.
Root Cause: Wrong entity used for grid "Production" - was using cumulative energy sensor (kWh) instead of instantaneous power sensor (W).
What Changed
OLD Configuration (Working)
grid:
entity:
consumption: "sensor.tagstromverbrauch_momentan" # Grid consumption
production: "sensor.tagstromverbrauch" # Grid feed-in
home:
use_metadata: true # Card auto-calculates: Solar + Grid = Home
NEW Configuration (Broken)
grid:
entity: "sensor.grid_verbrauch_gesamt" # Combined, consumption-only
home:
use_metadata: true # Can't calculate properly without grid feed-in data
✅ SOLUTION (User Found & Verified Working)
Use separated grid entities with correct sensors:
- Consumption:
sensor.grid_verbrauch_gesamt(Tag + Nacht combined in W) - Production:
sensor.tagstromverbrauch(instantaneous power in W)
Key: Must use tagstromverbrauch (power), NOT tagstromverbrauch_ausgehend (cumulative energy)!
Why This Works
- Includes both circuits:
grid_verbrauch_gesamtcombines Tagstrom + Nachtstrom (LOGAREX) - Correct unit:
tagstromverbrauchis instantaneous power (W), not cumulative energy (kWh) - Proper energy flow calculation: Card can now calculate: Home = Solar - Grid_Feed_in
- Verified working: Display shows Solar 3.1 kW → Home 317W, Grid -2.8 kW feed-in ✓
✅ Implementation (Already Done by User)
Configuration via Home Assistant UI
Power Flow Card Plus → Grid Section:
- Expand "Separated Entities" section
- Consumption: Select
Grid Verbrauch Gesamt - Production: Select
Tagstromverbrauch(NOTTagstromverbrauch_ausgehend!)
Result in /config/.storage/lovelace:
"grid": {
"display_state": "one_way",
"entity": {
"consumption": "sensor.grid_verbrauch_gesamt",
"production": "sensor.tagstromverbrauch"
},
"invert_state": false,
"use_metadata": false,
"secondary_info": {}
}
No Additional Steps Required
The card calculates home consumption automatically with use_metadata: true:
Home = Solar - Grid_Production + Grid_Consumption
= 3.1 kW - 2.8 kW + 0 kW
= 0.3 kW (300W) ≈ 317W shown ✓
Critical Files
- Power Flow Card Config:
/config/.storage/lovelace(SSH: icke@172.20.70.10) - Template Sensors:
/config/configuration.yaml - Git Repository:
/config/.git/(usesudo gitfor commands)
✅ Verified Behavior (Working)
Current Display (from user screenshot):
- Solar: 3.1 kW production
- Grid: -2.8 kW (negative = feeding to grid)
- Home: 317 W consumption
- Energy flows: Solar→Home (small line), Solar→Grid (large line)
Calculation verification:
Solar production: 3.1 kW
Home consumption: 0.317 kW
Excess to grid: 3.1 - 0.317 = 2.783 kW ≈ 2.8 kW ✓
✅ Verification Complete
User confirmed working configuration:
- ✅ Solar production displays correctly (3.1 kW)
- ✅ Grid shows negative value when feeding in (-2.8 kW)
- ✅ Home consumption realistic (317 W, not 3.1 kW)
- ✅ Energy flow arrows display correctly
Recommended Git Commit
Document this fix in git:
ssh icke@172.20.70.10
cd /config
sudo git add .storage/lovelace
sudo git commit -m "Fix: Power Flow Card Plus - Use correct sensors for grid consumption/production
Grid configuration:
- Consumption: sensor.grid_verbrauch_gesamt (Tag + Nacht combined, W)
- Production: sensor.tagstromverbrauch (instantaneous power, W)
Previous issue: Used tagstromverbrauch_ausgehend (cumulative kWh) which showed
as 38,550 kW instead of actual feed-in power.
Verified working: Solar 3.1kW → Home 317W, Grid feed-in -2.8kW
Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>"
Key Lesson Learned
The Problem Was NOT Missing Home Entity
The user initially thought: "we need to add some entity in the home section"
Actual problem: Grid "Production" was using wrong sensor type:
- ❌
tagstromverbrauch_ausgehend- cumulative energy (kWh) - totals 38,550! - ✅
tagstromverbrauch- instantaneous power (W) - shows ~2.8 kW
The card needs instantaneous power (W) for both consumption and production to calculate energy flows correctly.
Summary for Documentation
Problem: Power Flow Card showing all solar going to home (incorrect)
Root Cause: Grid production entity was cumulative energy (kWh) instead of instantaneous power (W)
Solution:
Grid → Separated Entities:
Consumption: sensor.grid_verbrauch_gesamt
Production: sensor.tagstromverbrauch (NOT tagstromverbrauch_ausgehend)
Result: Correct display showing solar → home (small) + solar → grid feed-in (large) ✓